Ca
1.7 Cu. Ft. Convection Over-the-Range
Microwave Oven
CVM517P4MW2 / CVM517P3MD1
© 2018 GE Appliances PC90238 05/18
DIMENSIONS AND INSTALLATION INFORMATION
(IN INCHES)
For answers to your Café™ product questions, visit our website at cafeappliances.com.
Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet
above microwave oven. No additional wiring, venting or cabinet rebuilding necessary in
many cases. Complete detailed, easy-to-follow installation instructions and convenient
full-size templates are packed with the microwave oven.
Important Information: When installing the microwave oven over a range, allow
minimum of 2" from bottom of microwave oven to top of range backguard to
allow for removal of light covers.
Ventilation Options: The microwave ovens are designed for adaptation to
the following three types of ventilation:
-Outside exhaust (vertical – as shown)
-Outside exhaust (horizontal)
-Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information: This information is not intended to be used for installing
unit described. Before installing, consult installation instructions packed with
product/kit for current dimensional data.
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT.
Read the following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6" diameter duct.
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equivalent length of all transitions
and adaptors plus the lengths of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
105°
Door open
(without obstruction)
24-1/2"
29-7/8"
16-1/2"
(rear)
15-1/2"
15-3/4"
13"
MAX.
12"
MIN.*
66" MIN.
Mounting
height from
floor
Minimum distance from
door hinge side to
adjacent wall should
equal 1/2"
30" MIN.
width
required
Exhaust outlet
connects to
3-1/4"x 10" duct
*Maximum depth
with JX15
Bump Out Kit is 16"
Bump Out Kit
sold separately.
Filler Panel Kits JX36DSS/DDS
When replacing a 36" range hood, this kit fills in the additional width to provide
a custom built-in appearance. For installation between cabinets only; not for
end-of-cabinet installation. Each kit contains two 3"-wide filler panels.
Filter Kit JX81H–Recirculating Charcoal Filter Kit To be used when the
microwave oven cannot be vented to the outside.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
OPTIONAL ACCESSORIES
(AVAILABLE AT ADDITIONAL COST)
CXOTRHKPMSS
Brushed Stainless
1 handle
(Standard on Matte Black)
CXOTRHKPMBT
Brushed Black
1 handle
CXOTRHKPMCU
Brushed Copper
1 handle
CXOTRHKPMBZ
Brushed Bronze
1 handle
(Standard on Matte White)
ADDITIONAL ACCESSORIES